One
Select issue
Year Issue
Article search ?
Author
Add authorDel author
Keyword
Add keywordDel keyword
Full text

all these words
this exact wording or phrase
one or more of these words
any of these unwanted words
Year
till
 
Two
You are here: Home Archive 2016 Canopy evapotranspiration, leaf transpiration and water use efficiency of an Andean pasture in SE-Ecuador – a case study

Article details

Canopy evapotranspiration, leaf transpiration and water use efficiency of an Andean pasture in SE-Ecuador – a case study

DOI: 10.3112/erdkunde.2016.01.02
Year: 2016
Vol: 70
Issue: 1
Pages: 5-18
Summary:

The relationship between canopy-level evapotranspiration (ETSci) and leaf-level transpiration (Tleaf) as well as photosynthesis (Pleaf) for a homogeneous tropical montane pasture was analyzed over five days using a combination of methods involving a laser scintillometer and a porometer. Weather conditions ranged from overcast to sunny during the period of study. The gas exchange of the leaves of the dominant pasture grass Setaria sphacelata (transpiration vs. photosynthetic CO2 net uptake ) was measured with a porometer and physiologically interpreted on the background of microclimate variables (photosynthetic active radiation (PAR) as proxy for total light intensity, temperature, water vapor deficit of the air) and soil moisture data. Water use efficiency (WUE, photosynthetic CO2 net uptake vs water loss by leaf transpiration) of the pasture was used to analyze the grass’ range of response to the environmental variables of the research area. PAR and water vapor deficit of the air (VPD) appeared to be the determinant factors for Tleaf and ETSci. WUE for the Setaria sphacelata pasture ranged from 1.9 to 5.8 µmol CO2 mmol-1 H20 day-1 and is particularly low during periods of high VPD combined with enhanced insolation during cloudless periods. ET measurements collected by the scintillometer demonstrated a strong correlation with water flux calculated using the Penman-Monteith approach (TPM) (r² = 0.95). Also, Tleaf measured with the porometer showed reasonable coincidence with the ET observations (r² = 0.78). Values of ETSci ranged from 2.26 to 4.96 mm day-1 and Tleaf ranged from 0.83 to 2.41 mm day-1, but only ETSci showed good correspondence with the available energy (net radiation). The lower correlation between Tleaf and canopy-level ETSci compared to that between ETSci and TPM was tested against contaminations from the adjacent fetch area of the scintillometer path, but no effects were found. Likewise, soil water limitations of Tleaf could be ruled out. Therefore, different correlations of ETSci and Tleaf with the incoming energy and VPD may be traced back to a direct effect of the VPD on ET in contrast to its indirect effect on Tleaf which is additionally regulated by physiological processes in the leaf stomata.

Zusammenfassung:

Eine Kombination von Laser-Szintillometer- und Porometer-Messungen wurde verwendet, um die Beziehung zwischen der Pfad-Evapotranspiration (ETSci) und der Blatt-Transpiration (Tleaf) sowie der photosynthetischen Netto-CO2 Aufnahme (Pleaf) für eine homogene tropisch-montane Weidefläche zu analysieren. Die Messungen erfolgten an fünf Tagen mit unterschiedlichen Wetterbedingungen (bewölkt bis wolkenfrei). Der Gasaustausch der Blätter des dominierenden Weidegrases Setaria sphacelata (Photosynthese-CO2-Nettoaufnahme versus Transpiration Tleaf) wurde mit einem Porometer gemessen und physiologisch auf der Basis von Mikroklimadaten (photosynthetisch aktive Strahlung PAR für Lichtintensität, Temperatur, Sättigungsdefizit der Luft) und der Bodenfeuchtigkeit interpretiert. Die Wassernutzungseffizienz (WUE, als Quotient aus Photosynthese-CO2-Nettoaufnahme und Wasserabgabe durch Blatttranspiration) wurde verwendet, um die Bandbreite der Reaktion der Weidefläche und des Grases auf die Umgebungsvariablen der Untersuchungsfläche zu analysieren. PAR und das Sättigungsdefizit der Luft (VPD) erscheinen als bestimmende Faktoren für Tleaf und ETSci. Die WUE von Setaria sphacelata ist bei hohem VPD und gleichzeitig hoher Sonneneinstrahlung bei wolkenlosem Himmel besonders niedrig. Die mit dem Szintillometer gemessenen Verdunstungsraten (2.26 bis 4.96 mm Tag-1) korrelieren sehr gut mit den mittels des Penman-Monteith Ansatz errechneten Werten für ET (r² = 0.95). Auch die mittels Porometer gemessene Blatttranspiration (0.83 bis 2.41 mm Tag-1) zeigt einen guten, wenn auch statistisch schwächeren Zusammenhang mit ETSci (r² = 0.78). Die geringere Korrelation zwischen Tleaf und ETSci resultierte nicht aus einer Signalkontamination durch Luftmassenadvektion aus dem Einzugsbereich (fetch) des Szintillometer-Pfads. Die Überprüfung zeigte keine derartigen Effekte. Bodenwasserlimitierung der Verdunstung konnte ebenfalls ausgeschlossen werden. Da ET direkt vom Wasserdampfsättigungsdefizit der Luft abhängt, die Verdunstung durch die Blätter aber hauptsächlich durch die Stomata erfolgt, sind physiologische Prozesse in der Stomataregulation für die etwas geringere Korrelation von ETSci und Tleaf im Tagesverlauf verantwortlich.

Document Actions